Everything you need to know about the Butler S and Butler M: technology, applications, safety, maintenance, rental and purchase.
50 kVA (45 kW), 25 kWh usable capacity, on a purpose-built trailer. Compact, for small to medium-sized construction sites, events and temporary power supply.
150 kWh net usable (185 kWh installed). The standard version delivers 100 kVA (90 kW); all Butler M units built so far are fitted with the additional power module and deliver 150 kVA (135 kW). For large construction sites, major events and critical emergency power supply.
A box that couples two Butler S units. Coupled, they deliver 100 kVA and 50 kWh instead of 50 kVA and 25 kWh each.
Based on our existing systems, we develop customised solutions for appropriate quantities (development costs borne by the customer).
| Butler S 50/25 | Butler M 100/150 | |
|---|---|---|
| Rated power | 50 kVA (45 kW); 2 × S with LinkDuo: 100 kVA / 50 kWh | 150 kVA (135 kW) for all systems built; standard 100 kVA (90 kW) |
| Usable capacity | 25 kWh | 150 kWh (185 kWh installed) |
| Cell type | Li-ion, LMO | Li-ion, NMC |
| Output voltage | 230/400 V AC ±5%, 50 Hz | 230/400 V AC, 50 Hz |
| Charging time | < 4.5 h (0–100%, 16 A) | < 4.5 h (5–95%, 63 A) |
| Operating temperature | −20 to +40 °C | −20 to +50 °C |
| Cooling | Air cooling | Industrial air-conditioning unit |
| Degree of protection | IP54 | IP54 |
| Dimensions (L × W × H) | 148 × 82 × 110.5 cm | 250 × 112 × 170 cm |
| Weight without trailer | approx. 640 kg | 2,850 kg (3,370 kg with trailer) |
| Noise | < 52 dB at 1 m | – |
| Service life | 11,000 cycles / 15 years | 3,500 cycles / 10 years |
Source: operating manuals Butler S and Butler M.
The Butler has been developed in Switzerland since 2018 and has been in field use since 2019. Today, around 200 Butlers are in operation across Europe:
Both models are continuously developed further; experience from the field flows directly into every new series.
emost is a system integrator: we specify the individual components and combine them with our own control electronics and IoT system. Quality assurance and final acceptance of every unit are carried out by emost.
All Butlers are developed in Switzerland. They are manufactured partly in Switzerland and partly in the EU.
Yes. After floods, storms or blackouts, power plants and major lines are restored first; it can take days until the local distribution grid is running again. The Butler bridges this gap:
Civil protection organisations have already procured the Butler.
Yes. The Butler has no combustion engine and produces no exhaust fumes, so it can readily be used indoors, e.g. for events in halls or for interior demolition.
Yes, with Boost mode. If the grid connection is not sufficient for the connected loads, the Butler switches to Boost mode automatically and without interruption: it is charged e.g. via a 16 A socket while simultaneously supplying loads of up to 50 kVA (Butler S) via the 16 A, 32 A or 63 A socket.
No grid expansion and no diesel required.
The Butler S has been in field use since 2019, is now in its 5th generation (GEN05) and has proven itself as a robust, largely trouble-free system. Examples from our use cases:
Two Butler S units protected six well pumps of 5.6 kW each against grid failure: up to 6 hours of emergency power depending on load, automatic SMS alerts on grid failure and remote monitoring. Diesel operation was reduced by 90%.
Without site power, a Butler S supplied three pumps and the grid failure monitoring for five weeks. A 20 kVA diesel generator recharged it, running only between approx. 35% and 70% state of charge. Diesel running time was reduced by 90%.
Night work with daily set-up and dismantling: the Butler S replaced the diesel generator. Workers needed neither hearing protection nor masks, and after every night shift the state of charge was still around 60%.
A sustainability event with catering, stage, lighting and live music in an enclosed hall ran 100% on a Butler M and a Butler S, without grid power. 123 kWh were consumed; peak power of the Butler M was 30 kW.
| 100–110% | continuous (30 min at 23 °C) |
| 110–125% | max. 10 min |
| 125–150% | max. 1 min |
| > 150% | max. 0.2 s |
This allows short inrush currents from motors, pumps or cranes to be absorbed. The power output may be limited depending on temperature.
CEE 400 V 32 A and CEE 400 V 16 A. Option: single-phase charging 230 V via C14 appliance inlet (home charging).
CEE 400 V 32 A, CEE 400 V 16 A and type 25 (CH) or Schuko 16 A. Options: CEE 63 A or an additional type 25 socket.
CEE 400 V 63 A and CEE 400 V 32 A. Options: additional CEE 16 A (230 V or 400 V), CCS Type 2 for DC charging stations.
CEE 400 V 16 A, 32 A and 63 A. Options on request: 2 × type 25 (CH) or 2 × Schuko (EU), additional CEE 16 A / 32 A, 125 A output (Powerlock).
The Butler delivers 230/400 V AC (±5%), 50 Hz, as a clean sine wave. This makes it suitable for sensitive loads such as medical equipment, IT and event technology.
Simultaneous charging and discharging is possible.
Usable capacity decreases in cold conditions. If the battery is too cold or too hot, the system blocks the charging plugs or sockets to protect the modules. The Butler must then be warmed up (e.g. in a heated room) or shaded.
Both models have IP54 protection (humidity up to 95%, non-condensing).
Do not clean with high-pressure or steam cleaners. When hosing down, no direct water jet may hit the ventilation slots on the underside.
This depends on the power of the connected loads and how long they run. Empirical values:
In grid or Boost mode, the Butler recharges continuously and can be used correspondingly longer. The remaining time is shown on the display.
No. Charging only takes place via the input plugged in first; further inputs are then inactive.
Switching on and off via a rotary switch; there is also an emergency stop switch. Start-up takes approx. 2 minutes.
The display shows, among other things, the state of charge (SoC), the power per phase and the remaining time. The status LED shows the state: steady green = ready for operation, flashing green = charging, red = starting/shutting down, emergency stop active or fault.
Yes. Around 120 data points from the battery, power electronics, GPS and system control are continuously transmitted to the emost cloud via a mobile network gateway.
The web application at app.emost.com runs in any browser, on computers and smartphones. It shows, among other things, location, state of charge, operating mode, temperature and the status of the battery and power electronics. The customer receives the login details on handover.
The stored data enable condition analyses and customer-specific reports. The service partner provides support via remote service.
emost must be informed in the event of resale; otherwise the SIM card will be deactivated.
The battery management system continuously monitors the modules. If the state of charge falls below 5%, the CEE sockets are switched off; the type 25/Schuko socket at 0%. They switch on again automatically from 10%.
According to information pursuant to the EU Battery Regulation 2023/1542 (capacity loss at end of life 30%):
When the Butler is connected to the grid by cable, it becomes part of the grid's protection concept, like a normal load. Only connect to power sources with a TN or TT system.
Without the grid, protective separation applies: the outputs are routed via miniature circuit breakers, built-in residual current devices (RCD) and insulation monitoring (IMD); the system has insulation equivalent to protection class II. This operating mode does not require installation by a qualified electrician.
Thanks to the built-in RCDs, the Butler (S and M) can be used without earthing in island mode and in grid mode on TN/TT systems. Without RCD protection, earthing would be required.
For this purpose, every Butler (S and M) has a connection for equipotential bonding (PE terminal on the control panel, e.g. for an earth rod). Correct installation must be verified by measurement by a qualified electrician. In the event of a fault without earthing, the unit and connected loads must not be touched.
The Butler M can be switched from IT system (without earthing) to TN system on the display within seconds.
emost issues an EU declaration of conformity (CE) for both models. The following were applied:
| Directive / standard | Content | S | M |
|---|---|---|---|
| Low Voltage Directive (LVD) 2014/35/EU | Electrical safety | ✓ | ✓ |
| EMC Directive 2014/30/EU | Electromagnetic compatibility | ✓ | ✓ |
| RoHS Directive 2011/65/EU | Restriction of hazardous substances | ✓ | ✓ |
| Battery Regulation (EU) 2023/1542 | Batteries and waste batteries | ✓ | |
| EN IEC 62040-1:2019/A11:2021 | UPS – Part 1: Safety requirements | ✓ | ✓ |
| EN 62040-2:2006/AC:2006 | UPS – Part 2: EMC requirements | ✓ | ✓ |
| IEC 62619:2022 | Safety of lithium batteries for industrial applications | ✓ | |
| IEC 62620:2014 | Lithium batteries for industrial applications | ✓ | |
| IEC 61429:1997 | Marking with the international recycling symbol | ✓ |
Source: EU declarations of conformity Butler S (08.10.2024) and Butler M 150/150 (29.06.2026).
In addition: the battery modules have passed the UN 38.3 transport test (prerequisite for transport according to UN 3536). Vibration tested according to AECTP-400 and IEC 60068-2-64.
The system is switched off; the battery is then completely disconnected from the rest of the system.
The battery management system (BMS) continuously monitors the modules and shuts down in the event of a fault. If temperatures are too high or too low, plugs and sockets are blocked.
In the event of severe external heating (e.g. a fire nearby), the battery can accelerate a fire. A distance of 5 m from areas at risk of fire or explosion therefore applies, and the unit must always be used in accordance with the operating manual. Modifications to the system are not permitted and void all warranties.
As standard on a trailer (Butler S: Agados or BTR trailer; Butler M: BTR trailer), ADR-compliant according to UN 3536.
Weight: Butler S approx. 640 kg without trailer; Butler M 2,850 kg without or 3,370 kg with trailer.
Very little: no engine, no oil or fuel filter changes as with a diesel generator.
In addition, scheduled replacement of electrical components such as fans and capacitors.
In the event of a fault, the display shows an error code. The customer first checks possible causes using the operating manual (chapter «Troubleshooting by the customer»). Do not attempt to rectify faults not described there yourself.
emost response time: within half a working day.
Please contact your dealer or emost directly; we ensure proper recycling. The disposal of Li-ion batteries is regulated differently depending on the country and region (in the EU, e.g. by the Battery Regulation).
emost AG, Hagackerstrasse 9, 8953 Dietikon, Switzerland, support@emost.com
Both: rental, rent-to-own, purchase and leasing, via our partners or directly from emost. In Switzerland, we offer rental with full service support.
Purchase prices on request. Rental prices depend on the number of units, rental period, how short-notice the request is, season and industry (rental request at www.emost.com).
Yes. Over the service life, operating costs are up to 60% lower than with a comparable diesel generator: no fuel, hardly any maintenance, no refuelling trips. Around 18 t of CO₂ per year can be saved per unit.
In hybrid mode with a small diesel generator, the generator's running time is reduced by up to 90% (use cases dewatering Biel and A6 Muri–Rubigen).
With stricter emission regulations and rising diesel prices, the advantage will continue to grow.
Standard warranty: 2 years or 3,000 operating hours, extendable to 5 years or 8,000 operating hours.
We guarantee operating hours rather than cycles because partial and full cycles are difficult to distinguish. With very intensive use, the warranty for the Butler S corresponds to about 6,000 cycles.
Modifications to the system void all warranties.
Purchase: two to four months depending on the order. Rental: quotation within 24 hours, set-up typically within 48 hours.
The DACH region (Germany, Austria, Switzerland) is very well covered; the Europe-wide network is being continuously expanded. For partners see www.emost.com.
We will be happy to advise you personally and can arrange an on-site test.